How to calculate temperature reduction in sub size specimen for Charpy Impact Test?

We need to know the way of calculation temperature reduction when we use sub size specimen. Problem: We have tested an A333 Gr.6 ...


We need to know the way of calculation temperature reduction when we use sub size specimen.

Problem:

We have tested an A333 Gr.6 (4" pipe 6.3 mm thickness). Laboratory used a sub size specimen (55*5*10) and tested it at -48c. test temperature of A 333 Gr.6 is -45C (3 degree Celsius cooler temperature) Unfortunately absorbed energy was low and the test was failed. We see a clause in standard (SA-333/SA-333M) which described that:

14.1.2) When sub size Charpy impact specimens are used and the width along the notch is less than 80% of the actual wall thickness of the original material

Is this clause applicable for this case??????

Really we don't know which one is correct?

  • (5/6.3) * 100 = 79% then we should not apply the above mentioned clause and we shall calculate reduction temperature and test my sample in cooler temperature(-45 + -3 = -48).
  • (10/6.3) * 100 = 159% then we should not apply the above-mentioned clause and no need to reduce temperature and test my sample in MDMT(-45).

2 comments

  1. (5/6.3) * 100 = 79% then we should not apply the above mentioned clause and we shall calculate reduction temperature and test my sample in cooler temperature(-45 + -3 = -48). This is correct, With small correction. Kindly check the note below Table 6 of SA/A 333 "Straight line interpolation for intermediate values is permitted. So by calculations -45 + -4=-49.

    SA/A 333 - 13.2 Test specimens shall be obtained so that the longitudinal axis of the specimen is parallel to the longitudinal axis of the pipe while the axis of the notch shall be perpendicular to the surface.

    SA/A 333 -14.1.2 When subsize Charpy impact specimens are used and the width along the notch is less than 80 % of the actual wall thickness of the original material,

    All sub size specimens will be 2.5x10, 5x10,7.5x10,etc. So for Impact specimen one width should be always 10mm and second width along the notch is restricted by thickness of the material being tested. Hope this clarifies

    ReplyDelete
  2. Great information, Thank you for sharing and keep posting.
    Also check - Diffusion Engineers is the best infrastructure in industry that involves into the wide range of welding consumable, welding electrodes maintenance, manufacturers and suppliers of wear plates and components in India.
    Wear Plates Manufacturers in India
    Welding Consumables Manufacturers
    Flux Cored Wire Manufacturers
    Welding Consumables
    Welding Electrodes Manufacturers in India
    Welding Electrodes Maintenance
    Welding Electrodes Manufacturers
    Flux Cored Wire Manufacturers in India
    Welding Consumables Suppliers in India
    Welding Consumables Manufacturers in India

    ReplyDelete